Illustrated title card for the guide: Fix OAG Prism Shadows in Flats and Use PHD2 Multi-Star

Plate 01 guiding From published documentation

Fix OAG Prism Shadows in Flats and Use PHD2 Multi-Star

Check a flat for an OAG prism shadow, adjust the prism, and inspect a captured image. Set up PHD2 multi-star guiding and check for secondary stars.

If your off-axis guider (OAG) prism casts a shadow in a flat frame, move the prism away from the imaging sensor’s field of view. Check an image captured at the adjusted prism position for any remaining obstruction. Focus the guide camera, enable multi-star guiding in PHD2, and use Auto-select Star while guide exposures are looping. OGMA prism placement and focus · QHYCCD prism adjustment · PHD2 star selection

Check the prism shadow in a flat

  1. Take an unsaturated flat through the main camera with the imaging train assembled and an evenly illuminated source such as a light box. Note where the suspect shadow appears in the frame. Flat capture in eloy · Siril flat calibration
  2. Move the prism outward. On the QHYOAG M/L Pro, loosen the prism-position locking knob on the side of the OAG and move the prism farther from the chip. QHYCCD Brief User Guide
  3. After adjusting the prism, check the same part of a captured image for an obstruction. For the OGMA OAG, the aim is to keep the prism close enough to pick up guide stars while leaving the imaging sensor’s field of view clear. QHYCCD prism adjustment · OGMA prism placement

Capture the calibration flats with the prism in the same position used for the light frames they will calibrate. eloy flat-field guidance

Focus the guide camera

For the OGMA OAG, focus the main imaging camera first. Then use the OAG’s helical focuser to sharpen the stars on the guide camera. On the QHYOAG M/L Pro, release the focus locking knob before turning the focusing ring and lock it again after focusing. Forcing the ring while locked can damage the focuser. OGMA focus order · QHYCCD focuser instructions

Start PHD2 multi-star guiding

  1. Connect the guide camera and mount using your PHD2 equipment profile. For a new profile, open Connect Equipment → Manage Profiles → New using wizard…. With an OAG, use the imaging telescope’s focal length and account for a separate reducer on the guide camera if fitted. PHD2 equipment profiles
  2. Click the Brain button to open Advanced Settings. On the Guiding tab, check Use multiple stars. On the Camera tab, clear Use subframes if it is available, since subframe guiding uses a single star. PHD2 main screen · PHD2 Advanced Settings
  3. Select a guide exposure in the main window. PHD2 suggests one to three seconds as a starting point. Click Loop Exposures, then Auto-select Star, then Guide. The Guide button starts calibration if needed and then begins guiding. PHD2 exposure guidance · PHD2 main screen

Check for secondary stars

When multi-star guiding is active, PHD2 shows a rectangle around the primary star and circles around the secondary stars. If you see only the primary, check the two settings above and use Auto-select Star again while exposures are looping. While exposures are looping, clicking a star in the image selects that star for single-star guiding. PHD2 multi-star display · PHD2 Advanced Settings

Auto-selection needs stars of adequate size and signal-to-noise ratio. If the field yields too few usable stars, check guide-camera focus, try a slightly longer guide exposure, and run Auto-select Star again. PHD2 star selection · PHD2 exposure and focus guidance

Evidence and limits. The steps were based on the OGMA and QHYCCD OAG documentation, the eloy and Siril flat-field documentation, and the PHD2 v2.6.13 User Manual. The documentation was checked on November 26, 2026. The steps were not run on equipment.

Sources

Published documentation this plate was drawn from

  1. OGMA Off-Axis Guider Manual
  2. QHYCCD QHYOAG M/L Pro Brief User Guide
  3. eloy Image Calibration
  4. Siril Calibration
  5. PHD2 v2.6.13 User Manual
  6. PHD2 Main Screen
  7. PHD2 Basic Use
  8. PHD2 Advanced Settings

Neighbouring plates