Consider the QHY5III200M if you use a QHYOAG and compatible desktop guiding software. For ASIAIR guiding, check ZWO’s detailed support list before choosing between the ASI174MM Mini and ASI220MM Mini. QHYOAG, QHY5III200M, ZWO ASIAIR FAQ
Camera specifications
| Monochrome camera | Active sensor dimensions | Resolution | Pixel size |
|---|---|---|---|
| QHYCCD QHY5III200M | 7.68 × 4.32 mm (calculated) | 1920 × 1080 | 4 µm |
For the QHY5III200M, multiply the published effective pixel count on each axis by 4 µm. That gives 7,680 µm across and 4,320 µm high. QHY5III200M specs
Match the sensor to the guide opening
An off-axis guider (OAG) diverts a small part of the telescope’s light to the guide camera. Look up the opening on the guide-camera side and compare its width and height with the sensor. OGMA OAG manual
In the field, check that the prism picks up guide stars while staying clear of the main camera’s field of view. A prism set too close to the imaging sensor can cast a shadow. OGMA OAG manual
Check the holder and software before buying
- Match the holder. QHYCCD lists a 1.25-inch interface for the QHY5III200M and says its QHYOAG helical focuser accepts QHY5III cameras. QHY5III200M specs, QHYOAG specs
- Check focus with the intended adapter. Check that you can match the backfocus distances for the imaging and guide cameras. QHYCCD lists the 200M’s back focus as 8 mm without its adapter and 17 mm with it. OGMA OAG manual, QHY5III200M specs
- Check your controller. ZWO lists its Mini cameras among the equipment ASIAIR supports. For the QHY5III200M, check support in your desktop guiding app and operating system. QHYCCD lists the camera in its Windows AllInOne compatibility table. ZWO ASIAIR FAQ, QHYCCD driver compatibility
Check focus and find a guide star
- Focus the main imaging camera first. Leave that focus in place while you adjust the guide camera in the next steps. OGMA OAG manual
- In PHD2, open Connect Equipment using the USB icon and connect the camera and mount. Select an exposure of 1 to 3 seconds as a starting point and click the loop button to see repeated guide frames. PHD2 basic use
- Click a visible star and open Star Profile. As you adjust the guide focuser, look for the smallest repeatable half-flux diameter (HFD) across several frames. If the profile has a flat top, select a fainter star to focus on. PHD2 basic use, PHD2 monitoring tools
- If you still see too few usable stars, adjust the exposure or move the mount. When usable stars appear consistently, click Auto-Select Star, then Guide to begin guiding. PHD2 basic use
Evidence and limits. Camera and OAG details are based on the manufacturers’ product documentation and the OGMA OAG manual. The software steps follow PHD2 v2.6.14. Documentation was checked on 2026-11-26. No hands-on testing was performed. PHD2 user manual