<?xml version="1.0" encoding="UTF-8"?><rss version="2.0" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Off Axis Guider Guide: Guiders, Prisms and Backfocus</title><description>Plain guides to off axis guiders, prisms and backfocus for astrophotography, built from published official documentation.</description><link>https://offaxisguiderguide.com/</link><language>en</language><atom:link href="https://offaxisguiderguide.com/rss.xml" rel="self" type="application/rss+xml"/><item><title>Off-Axis Guider Setups for Celestron EdgeHD 8, 9.25 and 11</title><link>https://offaxisguiderguide.com/posts/oag-setups-celestron-edgehd-8-9-25-11/</link><guid isPermaLink="true">https://offaxisguiderguide.com/posts/oag-setups-celestron-edgehd-8-9-25-11/</guid><description>Plan an off-axis guider setup for the Celestron EdgeHD 8, 9.25 or 11. Find the native and reduced back focus, calculate spacers, and focus both cameras.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Start your off-axis guider (OAG) setup with the distance to the main camera sensor. Allow &lt;strong&gt;105 mm&lt;/strong&gt; behind the EdgeHD 8’s 0.7x reducer, &lt;strong&gt;133.35 mm&lt;/strong&gt; at its native rear connection, or &lt;strong&gt;about 146 mm&lt;/strong&gt; behind the large rear connection or matching reducer on the EdgeHD 9.25 and 11. Include the OAG, adapters and camera in that distance. &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron’s spacing guide&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Where to measure EdgeHD back focus&lt;/h2&gt;
&lt;p&gt;Measure back focus to the &lt;strong&gt;main camera sensor&lt;/strong&gt;, using the reference surfaces listed in the table. The native distance on the EdgeHD 9.25 and 11 depends on whether the 3-inch-to-2-inch reducer plate is fitted. &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron’s EdgeHD back-focus table&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;EdgeHD model&lt;/th&gt;
&lt;th&gt;Native back focus&lt;/th&gt;
&lt;th&gt;Back focus with its 0.7x reducer&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;8&lt;/td&gt;
&lt;td&gt;133.35 mm from the baffle tube lock nut ring&lt;/td&gt;
&lt;td&gt;105 mm&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;9.25&lt;/td&gt;
&lt;td&gt;146.05 mm from the 3-inch baffle tube lock ring, or 133.35 mm from the 3-inch-to-2-inch reducer plate&lt;/td&gt;
&lt;td&gt;About 146 mm from the rear metal surface of the reducer&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;11&lt;/td&gt;
&lt;td&gt;146.05 mm from the 3-inch baffle tube lock ring, or 133.35 mm from the 3-inch-to-2-inch reducer plate&lt;/td&gt;
&lt;td&gt;About 146 mm from the rear metal surface of the reducer&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;EdgeHD 8 at 105 mm or 133.35 mm&lt;/h2&gt;
&lt;p&gt;With the reducer fitted, a DSLR and T-ring that together use &lt;strong&gt;55 mm&lt;/strong&gt; leave &lt;strong&gt;50 mm&lt;/strong&gt; (105 − 55) for the OAG and all hardware between the reducer and T-ring. Add up those parts before choosing spacers. At native focal length, start the same calculation at &lt;strong&gt;133.35 mm&lt;/strong&gt;. &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron’s DSLR and EdgeHD spacing&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;EdgeHD 9.25 and 11 at about 146 mm&lt;/h2&gt;
&lt;p&gt;On either model at native focal length, Celestron’s T-adapter for the large rear connection uses about &lt;strong&gt;91 mm&lt;/strong&gt;, leaving &lt;strong&gt;55 mm&lt;/strong&gt; (about 146 − 91) for the guider, spacers and camera. &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron’s T-adapter and EdgeHD spacing&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;As a camera-side spacing example, ZWO’s &lt;strong&gt;55 mm&lt;/strong&gt; layout for the ASI2600MM Pro shows the original OAG replacing the &lt;strong&gt;16.5 mm&lt;/strong&gt; T2-to-M48 extender. This layout uses no filter wheel or drawer. ZWO lists it as suitable for telescopes up to &lt;strong&gt;f/4.8&lt;/strong&gt; and warns that the original OAG partly obstructs the sensor with an &lt;strong&gt;M42&lt;/strong&gt; telescope-side connection. &lt;a href=&quot;https://us.zwoastro.com/blogs/usage-tutorials/asi2600-guide-4-connection-methods-to-get-55mm-back-focus-length-2&quot;&gt;ZWO’s original OAG connection example&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Set the spacer length and focus both cameras&lt;/h2&gt;
&lt;p&gt;Subtract the camera’s sensor setback and the installed lengths of the OAG, adapters and filter holder from the target to find the room for spacers. If you add filter glass, increase the spacing target by about a third of its thickness. For example, 3 mm of glass adds about 1 mm to the 105 mm target, giving 106 mm. &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron’s spacing and filter guidance&lt;/a&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Focus the main camera first. Keep it at its chosen spacing while you focus the guide camera. &lt;a href=&quot;https://www.touptekastro.com/pages/faqs&quot;&gt;ToupTek’s focus sequence&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;If the guide camera has trouble finding a star, adjust the prism position. &lt;a href=&quot;https://www.touptekastro.com/pages/faqs&quot;&gt;ToupTek’s OAG troubleshooting&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Take a short exposure of a bright star field with the main camera and check the corners. Celestron’s spacing guide suggests adding distance for stars stretched radially and reducing it for stars stretched around the center. &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron’s star-field check&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;em&gt;Evidence and limits.&lt;/em&gt; Celestron’s EdgeHD spacing guide, ZWO’s 55 mm connection guide and ToupTek Astro’s OAG troubleshooting were checked on November 27, 2026. No hands-on assembly or testing was performed.&lt;/p&gt;
</content:encoded><category>off-axis guiding</category><category>edgehd</category><category>back focus</category><category>focal reducers</category><author>Off Axis Guider Guide Editorial</author></item><item><title>ZWO OAG-L vs Player One MAX, Askar M54 &amp; Celestron OAG</title><link>https://offaxisguiderguide.com/posts/zwo-oag-l-vs-player-one-vs-askar/</link><guid isPermaLink="true">https://offaxisguiderguide.com/posts/zwo-oag-l-vs-player-one-vs-askar/</guid><description>Compare ZWO OAG-L, Player One FHD-OAG MAX, Askar M54 and Celestron OAG by prism size, adapters and camera fit, with a worked backfocus example.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Start with the &lt;strong&gt;ZWO OAG-L&lt;/strong&gt; if you use ZWO’s 2-inch or 36 mm filter wheel, or the &lt;strong&gt;Player One FHD-OAG MAX&lt;/strong&gt; if you use the Filter Drawer MAX. Shortlist the &lt;strong&gt;Askar M54&lt;/strong&gt; for its choice of threaded adapters, or the &lt;strong&gt;Celestron OAG&lt;/strong&gt; if you need the included SCT/EdgeHD adapter. Then check your guide camera and backfocus before buying.&lt;/p&gt;
&lt;h2&gt;Prism sizes and mounting options&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Off-axis guider&lt;/th&gt;
&lt;th&gt;Pickoff prism&lt;/th&gt;
&lt;th&gt;Imaging-train fit&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;ZWO OAG-L&lt;/td&gt;
&lt;td&gt;12 × 12 mm&lt;/td&gt;
&lt;td&gt;Built-in M48 tilt plate. ZWO lists its 2-inch and 36 mm electronic filter wheels. &lt;a href=&quot;https://www.zwoastro.com/product/zwo-off-axis-guider/&quot;&gt;ZWO specifications&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Player One FHD-OAG MAX, New Version&lt;/td&gt;
&lt;td&gt;8 × 14 mm&lt;/td&gt;
&lt;td&gt;Player One lists Poseidon, Zeus and Artemis camera series. The Filter Drawer MAX has a screw mount for the guider. &lt;a href=&quot;https://player-one-astronomy.com/product/fhd-oag-max-%EF%BC%88new-version%EF%BC%89/&quot;&gt;Guider specifications&lt;/a&gt; · &lt;a href=&quot;https://player-one-astronomy.com/product/filter-drawer-max/&quot;&gt;Filter Drawer MAX&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Askar M54 OAG&lt;/td&gt;
&lt;td&gt;10 × 10 mm&lt;/td&gt;
&lt;td&gt;M42, M48 and M54 thread options. &lt;a href=&quot;https://www.sharpstar-optics.com/Products_1/46.html&quot;&gt;Askar product page&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Celestron OAG&lt;/td&gt;
&lt;td&gt;12.5 mm&lt;/td&gt;
&lt;td&gt;Includes an SCT/EdgeHD adapter and male and female adapters in M42 and M48. &lt;a href=&quot;https://celestron.co.uk/products/off-axis-guider&quot;&gt;Celestron specifications&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Check both sides and the guide camera&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Match the imaging connections.&lt;/strong&gt; Write down the telescope or reducer connection and the mount on the filter hardware or imaging camera. For the Player One drawer, the telescope-side M2.5 holes take the OAG, and the camera-side holes take the cooled camera. &lt;a href=&quot;https://player-one-astronomy.com/product/filter-drawer-max/&quot;&gt;Filter Drawer MAX mounting instructions&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Match the guide camera and its focus position.&lt;/strong&gt; ZWO recommends an ASI Mini for the OAG-L, and Player One identifies its Xena-M as a match for the MAX prism. Celestron lists M42 T-thread and standard 1.25-inch guide-camera connections, plus 8 mm of helical focus travel. Confirm your guide camera can reach focus with your planned spacing. &lt;a href=&quot;https://www.zwoastro.com/product/zwo-off-axis-guider/&quot;&gt;ZWO specifications&lt;/a&gt; · &lt;a href=&quot;https://player-one-astronomy.com/product/fhd-oag-max-%EF%BC%88new-version%EF%BC%89/&quot;&gt;Player One specifications&lt;/a&gt; · &lt;a href=&quot;https://celestron.co.uk/products/off-axis-guider&quot;&gt;Celestron specifications&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Calculate backfocus before buying&lt;/h2&gt;
&lt;p&gt;Start at the reference surface in the telescope or reducer specification and end at the main camera sensor. If you use a glass filter, Celestron’s method adds one-third of the filter thickness to the target spacing. Subtract the camera’s sensor recess and the installed lengths of the filter wheel or drawer and other accessories. Compare what remains with the length of the guider &lt;strong&gt;with the adapters you’ll use&lt;/strong&gt;. &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron backfocus guide&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;ZWO lists the OAG-L at &lt;strong&gt;17.5 mm&lt;/strong&gt; thick. Player One lists &lt;strong&gt;17.5 mm&lt;/strong&gt; of extension for the FHD-OAG MAX. Add any extra adapter length for your setup. &lt;a href=&quot;https://www.zwoastro.com/product/zwo-off-axis-guider/&quot;&gt;ZWO specifications&lt;/a&gt; · &lt;a href=&quot;https://player-one-astronomy.com/product/fhd-oag-max-%EF%BC%88new-version%EF%BC%89/&quot;&gt;Player One specifications&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Suppose your target spacing after any filter correction is &lt;strong&gt;55 mm&lt;/strong&gt;. The Filter Drawer MAX uses &lt;strong&gt;21 mm&lt;/strong&gt;, and the Poseidon-C Pro with its tilt plate installed uses &lt;strong&gt;17.5 mm&lt;/strong&gt;. That leaves &lt;strong&gt;16.5 mm&lt;/strong&gt; for the guider. Adding the &lt;strong&gt;17.5 mm&lt;/strong&gt; FHD-OAG MAX brings the sum to &lt;strong&gt;56 mm&lt;/strong&gt; before any extra adapters. Player One lists &lt;strong&gt;12.5 mm&lt;/strong&gt; of camera backfocus with the Poseidon-C Pro’s tilt plate removed, so use the figure for your actual configuration. &lt;a href=&quot;https://player-one-astronomy.com/product/filter-drawer-max/&quot;&gt;Filter drawer&lt;/a&gt; · &lt;a href=&quot;https://player-one-astronomy.com/product/poseidon-c-pro-imx571-usb3-0-color-cooled-camera/&quot;&gt;Camera&lt;/a&gt; · &lt;a href=&quot;https://player-one-astronomy.com/product/fhd-oag-max-%EF%BC%88new-version%EF%BC%89/&quot;&gt;Guider&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; Manufacturer product pages and Celestron’s backfocus guide were checked on November 27, 2026. The Player One guider specs apply to the New Version (OAG-MAX-2). No hardware tests were performed.&lt;/p&gt;
</content:encoded><category>off-axis-guiding</category><category>backfocus</category><category>guide-cameras</category><category>astrophotography</category><author>Off Axis Guider Guide Editorial</author></item><item><title>Best Monochrome Guide Cameras for Off-Axis Guiding</title><link>https://offaxisguiderguide.com/posts/best-monochrome-guide-cameras-off-axis-guiding/</link><guid isPermaLink="true">https://offaxisguiderguide.com/posts/best-monochrome-guide-cameras-off-axis-guiding/</guid><description>Check the QHY5III200M for off-axis guiding. See how to match the camera to your guider, check backfocus and software support, and focus in PHD2.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Consider the &lt;strong&gt;QHY5III200M&lt;/strong&gt; if you use a QHYOAG and compatible desktop guiding software. For ASIAIR guiding, check ZWO&apos;s detailed support list before choosing between the &lt;strong&gt;ASI174MM Mini&lt;/strong&gt; and &lt;strong&gt;ASI220MM Mini&lt;/strong&gt;. &lt;a href=&quot;https://www.qhyccd.com/qhyoag/&quot;&gt;QHYOAG&lt;/a&gt;, &lt;a href=&quot;https://www.qhyccd.com/qhy5iii200m/&quot;&gt;QHY5III200M&lt;/a&gt;, &lt;a href=&quot;https://www.zwoastro.com/product-faqs/&quot;&gt;ZWO ASIAIR FAQ&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Camera specifications&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Monochrome camera&lt;/th&gt;
&lt;th&gt;Active sensor dimensions&lt;/th&gt;
&lt;th&gt;Resolution&lt;/th&gt;
&lt;th&gt;Pixel size&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;a href=&quot;https://www.qhyccd.com/qhy5iii200m/&quot;&gt;QHYCCD QHY5III200M&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;7.68 × 4.32 mm (calculated)&lt;/td&gt;
&lt;td&gt;1920 × 1080&lt;/td&gt;
&lt;td&gt;4 µm&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;For the QHY5III200M, multiply the published effective pixel count on each axis by 4 µm. That gives 7,680 µm across and 4,320 µm high. &lt;a href=&quot;https://www.qhyccd.com/qhy5iii200m/&quot;&gt;QHY5III200M specs&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Match the sensor to the guide opening&lt;/h2&gt;
&lt;p&gt;An off-axis guider (OAG) diverts a small part of the telescope&apos;s light to the guide camera. Look up the opening on the guide-camera side and compare its width and height with the sensor. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Guider&lt;/th&gt;
&lt;th&gt;Prism&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;a href=&quot;https://www.zwoastro.com/product-faqs/&quot;&gt;ZWO OAG&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;8 × 8 mm&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;a href=&quot;https://www.zwoastro.com/product-faqs/&quot;&gt;ZWO OAG-L&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;12 × 12 mm&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;In the field, check that the prism picks up guide stars while staying clear of the main camera&apos;s field of view. A prism set too close to the imaging sensor can cast a shadow. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Check the holder and software before buying&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Match the holder.&lt;/strong&gt; QHYCCD lists a 1.25-inch interface for the QHY5III200M and says its QHYOAG helical focuser accepts QHY5III cameras. &lt;a href=&quot;https://www.qhyccd.com/qhy5iii200m/&quot;&gt;QHY5III200M specs&lt;/a&gt;, &lt;a href=&quot;https://www.qhyccd.com/qhyoag/&quot;&gt;QHYOAG specs&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check focus with the intended adapter.&lt;/strong&gt; Check that you can match the backfocus distances for the imaging and guide cameras. QHYCCD lists the 200M&apos;s back focus as 8 mm without its adapter and 17 mm with it. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;, &lt;a href=&quot;https://www.qhyccd.com/qhy5iii200m/&quot;&gt;QHY5III200M specs&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check your controller.&lt;/strong&gt; ZWO lists its Mini cameras among the equipment ASIAIR supports. For the QHY5III200M, check support in your desktop guiding app and operating system. QHYCCD lists the camera in its Windows AllInOne compatibility table. &lt;a href=&quot;https://www.zwoastro.com/product-faqs/&quot;&gt;ZWO ASIAIR FAQ&lt;/a&gt;, &lt;a href=&quot;https://www.qhyccd.com/download/&quot;&gt;QHYCCD driver compatibility&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Check focus and find a guide star&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Focus the main imaging camera first. Leave that focus in place while you adjust the guide camera in the next steps. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;In PHD2, open &lt;strong&gt;Connect Equipment&lt;/strong&gt; using the USB icon and connect the camera and mount. Select an exposure of 1 to 3 seconds as a starting point and click the loop button to see repeated guide frames. &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 basic use&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Click a visible star and open &lt;strong&gt;Star Profile&lt;/strong&gt;. As you adjust the guide focuser, look for the smallest repeatable half-flux diameter (HFD) across several frames. If the profile has a flat top, select a fainter star to focus on. &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 basic use&lt;/a&gt;, &lt;a href=&quot;https://openphdguiding.org/man/Visualization.htm&quot;&gt;PHD2 monitoring tools&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;If you still see too few usable stars, adjust the exposure or move the mount. When usable stars appear consistently, click &lt;strong&gt;Auto-Select Star&lt;/strong&gt;, then &lt;strong&gt;Guide&lt;/strong&gt; to begin guiding. &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 basic use&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; Camera and OAG details are based on the manufacturers&apos; product documentation and the OGMA OAG manual. The software steps follow PHD2 v2.6.14. Documentation was checked on 2026-11-26. No hands-on testing was performed. &lt;a href=&quot;https://openphdguiding.org/man/&quot;&gt;PHD2 user manual&lt;/a&gt;&lt;/p&gt;
</content:encoded><category>off-axis guiding</category><category>guide cameras</category><category>astrophotography</category><category>autoguiding</category><author>Off Axis Guider Guide Editorial</author></item><item><title>OAG Parfocal Spacing and Prism-to-Sensor Distance</title><link>https://offaxisguiderguide.com/posts/oag-parfocal-spacing-prism-to-camera-distance/</link><guid isPermaLink="true">https://offaxisguiderguide.com/posts/oag-parfocal-spacing-prism-to-camera-distance/</guid><description>Calculate both prism-to-sensor distances for an off-axis guider, see which way to move the guide camera, and check that both cameras reach focus.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;For an initial fit on the OGMA off-axis guider (OAG), estimate the mechanical distances from the pick-off prism to the main and guide camera sensors and aim to match them. OGMA describes a shared light path and calls for matching the two cameras’ back-focus distances. Focus the main camera first, then adjust the guide camera until its stars are sharp at the same telescope focus. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Measure both paths from the prism&lt;/h2&gt;
&lt;p&gt;Follow the straight path toward the main camera and the path the prism diverts toward the guide camera. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The calculation below uses the pick-off prism as an approximate starting point for both mechanical estimates. If a camera’s sensor recess is specified from its mounting face, add the recess to the distance from the prism to that face. That first segment includes any adapters or spacers between the prism and the mounting face. &lt;a href=&quot;https://getogma.com/manual/ap26/back-focus&quot;&gt;OGMA camera manual&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Path&lt;/th&gt;
&lt;th&gt;Starting distance estimate&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Main camera&lt;/td&gt;
&lt;td&gt;Prism to main-camera mounting face + mounting face to main sensor&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Guide camera&lt;/td&gt;
&lt;td&gt;Prism to guide-camera mounting face at its current position + mounting face to guide sensor&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Worked example&lt;/h3&gt;
&lt;p&gt;OGMA documents a 20 mm adapter between its OAG and main camera for a setup without a filter wheel or holder. Its AP26CC and AP26MC cameras have a 17.5 mm sensor recess from the front face. &lt;a href=&quot;https://getogma.com/manual/OAG/20mm-adapter&quot;&gt;OGMA adapter instructions&lt;/a&gt; · &lt;a href=&quot;https://getogma.com/manual/ap26/back-focus&quot;&gt;OGMA camera manual&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The adapter and recess add up to &lt;strong&gt;20 mm + 17.5 mm = 37.5 mm&lt;/strong&gt;. Add the distance from the prism to the OAG&apos;s camera-side face to get the full main-side estimate. Use that total as the starting target for the guide path.&lt;/p&gt;
&lt;h2&gt;Use the difference to choose an adjustment&lt;/h2&gt;
&lt;p&gt;The table uses arithmetic to turn the two starting estimates into an initial adjustment. Subtract the guide-side estimate from the main-side estimate. The sign tells you which way to move the guide camera.&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Main distance minus guide distance&lt;/th&gt;
&lt;th&gt;Guide camera adjustment&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Positive&lt;/td&gt;
&lt;td&gt;Move the guide sensor away from the prism by the estimated difference.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Negative&lt;/td&gt;
&lt;td&gt;Move the guide sensor toward the prism by the magnitude of the difference.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Zero&lt;/td&gt;
&lt;td&gt;Start at the current position and fine-focus on a star.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;After setting an initial position, adjust the guide camera until the guide stars are sharp, as OGMA directs. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the guide path on the Opticstar OAG is 10 mm short, its 10 mm extension can move the guide camera’s focal plane that much farther from the guider. Opticstar also documents using the extension on the main side when that path needs more length. &lt;a href=&quot;https://www.opticstar.com/Opticstar-Off-Axis-Guider.html&quot;&gt;Opticstar OAG documentation&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Keep the optics&apos; back focus in the calculation&lt;/h2&gt;
&lt;p&gt;If the reducer or flattener documentation gives a back-focus distance and reference surface, check the distance from that surface to the main sensor before changing the main-side stack. Include the OAG and other parts in that total. A glass filter in the imaging path can also change the back focus needed. &lt;a href=&quot;https://getogma.com/manual/ap26/back-focus&quot;&gt;OGMA camera manual&lt;/a&gt; · &lt;a href=&quot;https://www.celestron.com/blogs/knowledgebase/back-focus-for-astrophotography-how-to-get-perfect-spacing&quot;&gt;Celestron back-focus guide&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Focus the main camera first&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Bring the main camera to focus. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Keep the main camera at that focus setting. Adjust the OAG&apos;s guide-camera focuser until the guide stars are sharp. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA OAG manual&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; The linked manufacturer documentation was checked on November 26, 2026. The calculations use published dimensions for the named hardware. No hands-on testing was performed.&lt;/p&gt;
</content:encoded><category>oag</category><category>parfocal</category><category>back-focus</category><category>guide-camera</category><author>Off Axis Guider Guide Editorial</author></item><item><title>Fix OAG Prism Shadows in Flats and Use PHD2 Multi-Star</title><link>https://offaxisguiderguide.com/posts/oag-prism-shadows-flat-frames-phd2-multi-star/</link><guid isPermaLink="true">https://offaxisguiderguide.com/posts/oag-prism-shadows-flat-frames-phd2-multi-star/</guid><description>Check a flat for an OAG prism shadow, adjust the prism, and inspect a captured image. Set up PHD2 multi-star guiding and check for secondary stars.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;If your off-axis guider (OAG) prism casts a shadow in a flat frame, move the prism away from the imaging sensor&apos;s field of view. Check an image captured at the adjusted prism position for any remaining obstruction. Focus the guide camera, enable multi-star guiding in PHD2, and use &lt;strong&gt;Auto-select Star&lt;/strong&gt; while guide exposures are looping. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA prism placement and focus&lt;/a&gt; · &lt;a href=&quot;https://www.qhyccd.com/qhyoag-l-pro/&quot;&gt;QHYCCD prism adjustment&lt;/a&gt; · &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 star selection&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Check the prism shadow in a flat&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Take an unsaturated flat through the main camera with the imaging train assembled and an evenly illuminated source such as a light box. Note where the suspect shadow appears in the frame. &lt;a href=&quot;https://eloy.readthedocs.io/en/latest/calibration/&quot;&gt;Flat capture in eloy&lt;/a&gt; · &lt;a href=&quot;https://siril.readthedocs.io/en/stable/preprocessing/calibration.html&quot;&gt;Siril flat calibration&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Move the prism outward. On the &lt;strong&gt;QHYOAG M/L Pro&lt;/strong&gt;, loosen the prism-position locking knob on the side of the OAG and move the prism farther from the chip. &lt;a href=&quot;https://www.qhyccd.com/qhyoag-l-pro/&quot;&gt;QHYCCD Brief User Guide&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;After adjusting the prism, check the same part of a captured image for an obstruction. For the OGMA OAG, the aim is to keep the prism close enough to pick up guide stars while leaving the imaging sensor&apos;s field of view clear. &lt;a href=&quot;https://www.qhyccd.com/qhyoag-l-pro/&quot;&gt;QHYCCD prism adjustment&lt;/a&gt; · &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA prism placement&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;Capture the calibration flats with the prism in the same position used for the light frames they will calibrate. &lt;a href=&quot;https://eloy.readthedocs.io/en/latest/calibration/&quot;&gt;eloy flat-field guidance&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Focus the guide camera&lt;/h2&gt;
&lt;p&gt;For the OGMA OAG, focus the main imaging camera first. Then use the OAG&apos;s helical focuser to sharpen the stars on the guide camera. On the &lt;strong&gt;QHYOAG M/L Pro&lt;/strong&gt;, release the focus locking knob before turning the focusing ring and lock it again after focusing. Forcing the ring while locked can damage the focuser. &lt;a href=&quot;https://getogma.com/manual/OAG/intro&quot;&gt;OGMA focus order&lt;/a&gt; · &lt;a href=&quot;https://www.qhyccd.com/qhyoag-l-pro/&quot;&gt;QHYCCD focuser instructions&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Start PHD2 multi-star guiding&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Connect the guide camera and mount using your PHD2 equipment profile. For a new profile, open &lt;strong&gt;Connect Equipment → Manage Profiles → New using wizard...&lt;/strong&gt;. With an OAG, use the imaging telescope&apos;s focal length and account for a separate reducer on the guide camera if fitted. &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 equipment profiles&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Click the &lt;strong&gt;Brain&lt;/strong&gt; button to open &lt;strong&gt;Advanced Settings&lt;/strong&gt;. On the &lt;strong&gt;Guiding&lt;/strong&gt; tab, check &lt;strong&gt;Use multiple stars&lt;/strong&gt;. On the &lt;strong&gt;Camera&lt;/strong&gt; tab, clear &lt;strong&gt;Use subframes&lt;/strong&gt; if it is available, since subframe guiding uses a single star. &lt;a href=&quot;https://openphdguiding.org/man/MainScreen.htm&quot;&gt;PHD2 main screen&lt;/a&gt; · &lt;a href=&quot;https://openphdguiding.org/man/Advanced_settings.htm&quot;&gt;PHD2 Advanced Settings&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Select a guide exposure in the main window. PHD2 suggests one to three seconds as a starting point. Click &lt;strong&gt;Loop Exposures&lt;/strong&gt;, then &lt;strong&gt;Auto-select Star&lt;/strong&gt;, then &lt;strong&gt;Guide&lt;/strong&gt;. The &lt;strong&gt;Guide&lt;/strong&gt; button starts calibration if needed and then begins guiding. &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 exposure guidance&lt;/a&gt; · &lt;a href=&quot;https://openphdguiding.org/man/MainScreen.htm&quot;&gt;PHD2 main screen&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Check for secondary stars&lt;/h2&gt;
&lt;p&gt;When multi-star guiding is active, PHD2 shows a rectangle around the primary star and circles around the secondary stars. If you see only the primary, check the two settings above and use &lt;strong&gt;Auto-select Star&lt;/strong&gt; again while exposures are looping. While exposures are looping, clicking a star in the image selects that star for single-star guiding. &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 multi-star display&lt;/a&gt; · &lt;a href=&quot;https://openphdguiding.org/man/Advanced_settings.htm&quot;&gt;PHD2 Advanced Settings&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Auto-selection needs stars of adequate size and signal-to-noise ratio. If the field yields too few usable stars, check guide-camera focus, try a slightly longer guide exposure, and run &lt;strong&gt;Auto-select Star&lt;/strong&gt; again. &lt;a href=&quot;https://openphdguiding.org/man/Basic_use.htm&quot;&gt;PHD2 star selection&lt;/a&gt; · &lt;a href=&quot;https://openphdguiding.org/man/Advanced_settings.htm&quot;&gt;PHD2 exposure and focus guidance&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;em&gt;Evidence and limits. The steps were based on the OGMA and QHYCCD OAG documentation, the eloy and Siril flat-field documentation, and the &lt;a href=&quot;https://openphdguiding.org/manual/&quot;&gt;PHD2 v2.6.13 User Manual&lt;/a&gt;. The documentation was checked on November 26, 2026. The steps were not run on equipment.&lt;/em&gt;&lt;/p&gt;
</content:encoded><category>off-axis-guiding</category><category>flat-frames</category><category>phd2</category><category>astrophotography</category><author>Off Axis Guider Guide Editorial</author></item></channel></rss>